Manual Part No: 11028854 MODEL EM405D USER'S MANUAL ETHERNET M- MODULE CARRIER
4 1.7 APPLICABLE DOCUMENTS ANSI/VITA 12-1996 American National Standard for The Mezzanine Concept M-Module Specification, Approved May 20
5 2.0 INSTALLATION 2.1 UNPACKING AND INSPECTION Verify that there has been no damage to the shipping container. If damage exists the
6 There are two M-module mounting locations on the EM405D. Single-wide M-modules may be installed in either or both of the positions. A double-wide
7 3.0 FUNCTIONAL DESCRIPTION 3.1 GENERAL The EM405D provides a mechanical and electrical interface between an Ethernet bus and up to two M-modules.
8 3.1.3 M-module Interface The M-module interface provides the mechanism for the microcontroller to access the M-modules. It is implemented
9 3.3 FRONT PANEL The front panel of the EM405D contains two openings for access to the M-modules’ front panel connections and three LED indicators
11 4.0 OPERATING INSTRUCTIONS 4.1 GENERAL The EM405D is controlled through the Ethernet interface using the TCP/IP protocol to carry a simple comman
12 RECOMMENDATION The EM405D is an embedded device without an input device or display that can be used to determine the current configurati
13 of other tasks. In ad-hoc mode, wireless devices may communicate directly with each other and an access point is not needed. In this case, all de
ii COPYRIGHT C&H Technologies, Inc. (C&H) provides this manual "as is" without warranty of any kind, either express
14 4.2.6.1 Wed-based Configuration To use the wed-based interface to configure the wired EM405D, open a Java enabled web browser and e
15 always starting with 00-20-4A identifying the manufacturer of the device. The last three parts of the number are unique to each unit. Exa
16 4.2.7.1 Wed-based Configuration To use the wed-based interface to configure the wireless EM405D, open a web browser and enter the device’s IP add
17 The defaults that are restored using the above procedure are those set by the manufacturer of the Ethernet device and not by C&H Technologies,
18 Successful (0x00): The command completed successfully without error. Invalid Command (0x01): The first byte received was not a valid command-id
19 4.3.2 Write Data command The Write Data command writes data to an EM405D control register or to a register residing on an M-module. The command
20 Example (values shown hex): To read the Device Identification Register on the EM405D, send the following command: Command: cd md as ws a
21 Example 4: Read 32 words starting at address 0x0 followed by 32 words starting at address 0x80 starting address = 0x0 block size = 32
22 4.3.4.2 Block Read command The Block Read command reads a block of data from an M-module. Unlike the block write command, block read does
23 4.3.5 EM405D Configuration/Status Registers The EM405D contains a set of registers that are used to identify the carrier, configure the carrier,
iii DOCUMENT REVISION NOTICE C&H Technologies, Inc. makes every attempt to provide up-to-date manuals with the associated equipment. Occasion
24 Reg. 00 Reset Error & Manufacturer Identification Byte 1 0 Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Write RERR - - - R
25 Reg. 08 Reset & Trigger Control Byte 9 8 Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Write RSTB RSTA TLVL TIMP BTBD BTBM
26 4.4 CONTROLLING THE TRIGGERS The carrier implements flexible trigger control capabilities providing the user with many options for using triggers
27 The function of each M-module trigger line is fully dependent upon the M-module. Refer to the particular M-module’s documentation for further deta
28
A-1 APPENDIX A - CONNECTORS Figure A-1. 9-Pin DSUB Connector PIN DESCRIPTION 1 +12V INPUT 2 +12V INPUT 3 +12V INPUT 4 TRIG
A-2
B-1 APPENDIX B – WIRED ETHERNET DEFAULT SETTINGS The Ethernet interface device on the wired version of the EM405D contains many configurable setti
B-2 Table B-1. Ethernet Interface Default Settings. (continued) Active Connection Active Connection None Telnet Mod N/A Terminal Type N/A Rem
B-3 Table B-1. Ethernet Interface Default Settings. (continued) Email Notification Domain Name blank Mail Server 0.0.0.0 Recipients (Collect
iv INTRODUCTION This manual describes the operation and use of the C&H Model EM405D Ethernet M-Module Carrier (Part Number 11028850). T
B-4
C-1 APPENDIX C – WIRELESS ETHERNET (Wi-Fi) DEFAULT SETTINGS The Ethernet interface device on the Wireless version of the EM405D contain
C-2 Table C-1. Wireless Ethernet Configuration Default Settings. (continued) Enable Line Printer Daemon (LPD) True - Port 515 Enable RealPort
C-3 Table C-1. Wireless Ethernet Configuration Default Settings. (continued) Advanced Serial Settings Enable Port Logging False Enable RTS Togg
C-4
N O T E S:
READER'S COMMENT FORM Your comments assist us in improving the usefulness of C&H's publications; they are an importan
INSTRUCTIONS In its continuing effort to improve documentation, C&H Technologies, Inc. provides this form for use in submitting any comments
v TABLE OF CONTENTS 1.0 GENERAL DESCRIPTION... 1 1.1 PURPO
vi 4.3.5 EM405D Configuration/Status Registers ...23 4.4 CONTROLLING THE TRIGGERS..
1 1.0 GENERAL DESCRIPTION The EM405D Ethernet M-Module carrier provides complete Ethernet connectivity to up to two industry standard single-wide or
2 1.2.2 Specifications MAXIMUM RATINGS Parameter Condition Rating Units Operating Temperature 0 to +60 C Non-Operating Temperature -40 to
3 1.3 Electrical The EM405D only requires a +12V DC power input. The +12V input is internally converted to the +3.3V power required by the carrier a